Pulse controller bag dust removal pulse instrument
This is a three-in-one integrated control instrument that combines an online pulse controller, a differential pressure display, and a differential pressure sensor, perfectly achieving resource optimization.
The control panel features a digital display that sequentially shows the operating sequence of the electromagnetic pulse valves. Pulse width, pulse interval, cycle interval, and output circuit can be adjusted according to dust removal requirements to control the opening and closing of the electromagnetic valves, enabling timed dust removal of the dust collector. It can also be switched to differential pressure cleaning; simply connect an air pipe to the unit to achieve intelligent control through a combination of seven differential pressure parameters.
To allow users to freely combine the number of electromagnetic pulse valves they control, an expansion output module is used, which can freely increase or decrease the number of controllable valves.
Specifications of SXC-X8A5 Differential Pressure Integrated Online Pulse Controller:
|
model |
Number of control electromagnetic pulse valves |
type |
Number of expansion modules |
Main shell dimensions (mm) H (height) × W (width) × L (depth) |
Expansion module dimensions (mm) H (height) × W (width) × L (depth) |
Net weight (kg) |
|
SXC-X8A5-XX |
1-16 |
single-player |
0 |
100*250*220 |
1.7 |
|
|
17-26 |
combination |
1 |
100*250*220 |
55*130*190 |
2.3 |
|
|
27-36 |
1 |
100*250*220 |
55*130*190 |
2.3 |
||
|
37-46 |
1 |
100*250*220 |
55*130*190 |
2.3 |
||
|
47-56 |
1 |
100*250*220 |
55*130*190 |
2.3 |
||
|
57-96 |
2 |
100*250*220 |
(55*130*190)*2 |
2.9 |
Shell material: Transparent PC plastic shell
Technical parameters and specifications:
|
Rated input voltage |
AC220V (±10%) 50HZ/60HZ |
|
Rated output voltage |
DC24V/AC220V (or other customized specifications) |
|
Rated output current |
1A |
|
Power consumption |
≤8W |
|
Output pulse width adjustment range |
0.02-2.55S |
|
Output pulse interval adjustment range |
1-255S |
|
Period (the time interval between one complete pulse valve cycle and the next cycle) |
0-255Min |
|
Pressure measurement range |
0-3KPa |
|
Control the number of electromagnetic pulse valves |
1-96 |
|
Control method |
Timed/Differential Pressure |
|
Differential pressure control input signal |
Differential pressure controller and differential pressure transmitter |
|
Usage Environment |
Operating temperature: -20℃ to +50℃; relative humidity: not exceeding 85%; There are no severely corrosive gases or conductive dust; there is no |