Deskripsi
Magphant Electromagnetic Flowmeter
The cost-effective limit switch for reliable and repeatable flow monitoring
- Category : FLOWMETER
- Product Name : MAGPHANT
- Model : DTI200-A11A1A
- Pipe Diameter : A1 : DN 25-2000 / 1″-80″ (steel)
- Process Connection : 1 : Welding nipple DN25 / 1″, steel, NBR
- Cable Entry : A : Gland PG16
- Approval : 1 : Non-hazardous area
- Accessory : A : Basic version
- Brand : ENDRESS+HAUSER
The economical, compact Magphant flow switch is suited to water applications in utilities. It offers high repeatability, reliably monitors flow, is simple and convenient to operate, and contributes to process and plant safety.
Benefits :
High plant availability – reliable flow information
Energy-saving flow measurement: no throttling components, ensuring no pressure loss
Maintenance-free: no moving parts
Process safety: the device has a self-monitoring function and monitors reliably even when the pipe is empty
Product safety: built-in test function ensures the electronics function correctly
Easy operation: electronic setting of the full-scale value
Application areas :
Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity
Widely used in various water applications in the utilities sector.
Instrument features
Compact design saves installation space
Nominal diameter: DN 15…2000 (1/2…80″)
Can be installed in steel or plastic pipes
Switch point set via rotary switch
Current output and relay output
ATEX, FM, CSA approvals
Liquids
| Measuring Principle | Electromagnetic |
| Product headline | . |
| Sensor features | High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80″). |
| Transmitter features | Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output. |
| Nominal diameter range | DN15 to DN2000 1/2″ to 80″ |
| Wetted materials | 1.4435/316L |
| Measured variables | Volume flow |
| Max. measurement error | 2% |
| Measuring range | 0 to 56’550 m3/h |
| Max. process pressure | 0 to 16 bar abs |
| Medium temperature range | -20 to +120°C (-4 to +248°F) |
| Ambient temperature range | -20…60 °C (-4 to 140°F) |
| Sensor housing material | Die-cast aluminium, epoxy powder coated |
| Degree of protection | IP 66 / NEMA 4X / Type 4X |
| Display/Operation | Test function |
| Outputs | 4 to 20 mA Relay |
| Inputs | None |
| Power supply | 24 V DC (20…30 V DC) |
| Hazardous area approvals | FM CSA |
| Product safety | CE, EAC |






Ulasan