SXY5S Intelligent Liquid Level Monitor

Rp0

Price : INQUIRY
Status : PRE-ORDER
MOQ : 1 PCS
Delivery Time : 4 – 6 Weeks
Delivery Point : Warehouse Jakarta – Indonesia

Stok 100

SKU: BTG/ACS/SXY5S Kategori: , Tag: Brand:

Deskripsi

Intelligent Liquid Level Monitor

Model : SXY5S
Power supply voltage : 220
External dimensions : 80*160(mm)
Resolution : 1
Measurement accuracy : 0.1
Specification : SXY5S Intelligent Liquid Level Monitor
SXY5S/SXY4S/SXY2S Intelligent Liquid Level Monitor :
The SXY5S intelligent universal electric contact liquid level monitor is an electric contact type liquid level measurement, display, and control instrument composed of a measuring cylinder, ultra-pure ceramic electrodes, and a display instrument. It uses red and green dual-color LEDs to simulate steam (red) and water (green) in the display, clearly indicating the liquid level position in the container, and has functions such as over-limit alarm and output. The SXY5S intelligent electric contact liquid level monitor has advantages such as simple structure, intuitive display, reliable operation, low maintenance, and convenient fault diagnosis and troubleshooting. It uses all-electric signal transmission, which not only has low delay but also eliminates the variation and scale error caused by mechanical transmission, eliminating the need for error calculation and adjustment. A prominent advantage of electric contact liquid level gauges is their adaptability to boiler variable parameter operation. Under variable parameter operation conditions such as boiler start-up and shutdown, the instrument can accurately display the water level in the control room. The SXY5S electric contact liquid level monitor is suitable for liquid level measurement and control of conductive liquids. It is mainly used for monitoring the water level in boiler steam vents, high and low pressure heaters, deaerators, evaporators, condensers, once-through boiler start-up separators, and other water tanks. However, it is not suitable for flammable or explosive environments.
Naming method:

name scale model Measuring cylinder parameters Installation method
SXY5S   *** (three-digit number) **(Two-digit number) (Horizontal or vertical)
I. Please refer to the attached table for scale models. Special specifications can be customized according to user needs.
II. Measuring cylinder parameters
III. Installation Method
            01—Working pressure ≤ 6.4MPa; Z—Vertical installation
            02—Working pressure ≤16MPaH—Horizontal installation
            03—Working pressure ≤20MPa
            04—Working pressure ≤22MPa
IV. Characteristics:
      1. The instrument’s display section uses both analog and digital displays simultaneously, providing a very intuitive and real-time display of water level rises and falls. The number of display points can be arbitrarily set within the range of 6 to 19 points according to user needs. Each scale value can be arbitrarily set via the panel operation, and the scale can be easily replaced according to the scale value, overcoming the shortcomings of old-fashioned instruments such as poor versatility, non-interchangeability, and numerous requirements for spare parts specifications. It has audible and visual alarms for exceeding liquid level limits and multiple alarm mode selection functions. The alarm point position can be arbitrarily set within the scale range. It has automatic water resistance judgment and tracking functions. This instrument can test each electrode individually and can display the water resistance (vapor resistance) value at each point, allowing you to promptly detect and judge whether the electrode is working properly, helping you decide whether the entire electrode set needs cleaning or replacement, and accurately providing adjustment parameters for the vapor-liquid critical surface value. It possesses strong fault tolerance. Thanks to intelligent water level recognition technology, even in the event of individual electrode malfunctions, the instrument can still display the correct water level value and immediately indicate the abnormal electrode on the panel scale by flashing, reminding you to perform maintenance and replacement. This overcomes the defect of older instruments where electrode damage could only be detected after it occurred. It has strong anti-interference capabilities, employing superior digital filtering technology in the input stage and a hysteresis-based electrode status judgment function, greatly improving the instrument’s reliability and anti-interference ability. The output stage uses a delayed alarm to prevent false alarms under conditions of strong instantaneous interference. The current output adopts a high-precision linear output method (determined according to the set value of the scale range), avoiding the non-linear output of older instruments and the limitations of signal transmission in DCS systems.  
     2. SXY5S/ SXY4S/SXY2S intelligent universal liquid level monitors can replace all older electrical contact liquid level monitors. All their interfaces are compatible with older instruments, allowing for direct replacement without any modifications.
     3. Technical parameters: Liquid water resistance range: 0—500kΩ (automatic tracking)
Simulation display: A set of color-changing LEDs (up to 19 points, special specifications can reach 38 points) display the real-time liquid level value in a red for steam and green for water, in conjunction with the scale.
     4. Digital Display: One-digit, three-digit (or four-digit) digital display shows the real-time liquid level value. Lead length from ultra-pure ceramic electrode to secondary instrument: ≤200m. Isolation Output: 0~10mA (RL<1kΩ=, 4~20mA (RL<500Ω) (linear)
     5. Alarm output contact capacity: AC220V, 1A; Provides four sets (two for upper and two for lower limits) of normally open and normally closed contacts. For special requirements, six sets are available, and five or four sets can be configured in different combinations (three up and three down, three up and two down, two up and three down, three up and one down, one up and three down) of normally open contacts. Internal DC battery power supply time ≥ 1 hour.
     6. Operating power supply: AC220V±10%, 50Hz±1Hz
     7. Instrument operating conditions: Ambient temperature: -10℃~+45℃;
     8. Relative humidity: ≤85%
     9. Instrument opening size: 152+1×76+1 or 152+1×152+1mm
   10. Instrument External Dimensions:
           Vertical format : 80×160×150mm (width×height×length)
           Square: 160×160×150mm (width×height×length)
           Horizontal: 160×80×300mm (width×height×length)
           Wall-mounted: 173×225×80mm (width×height×thickness)
    11.  Instrument wiring method: plug type wiring (the meter head plug is pin type, and the wire side plug is hole type). If there are special requirements, terminal type can also be customized by asking the customer.