Deskripsi
Ultrasonic Measurement Time-of-Flight Prosonic FMU30
- Category : LEVEL MEASUREMENT
- Model: FMU30-AAHEABGHF
-
Approval (AA) : Non-hazardous area
-
Display; Operation (H) : Envelope curve display on site; push button
-
Electrical Connection (E) : Gland M20, IP68
-
Sensor; Max Range; Blocking Distance (AB) : 2″; 8m liquid/ 3.5m solid; 0.35m
- Process Connection (GHF) : Thread ISO228 G2, PP
- Manufacturer: ENDRESS HAUSER AG
SPECIFICATIONS:
Measuring / Application task : Continuous / Liquids
Measuring principle : Ultrasonic
Characteristic / Application : Compact ultrasonic transmitter
Supply / Communication : 2-wire
Accuracy : +/- 3 mm or +/- 0,2 % of set measuring range
Ambient temperature : -20 °C … 60 °C (-4 °F … 140 °F)
Process temperature : -20 °C … 60 °C (- 4°F … 140 °F)
Process pressure / max. overpressure limit : 0.7 bar … 3 bar abs (10 psi … 44 psi)
Main wetted parts : PP/EPDM
Process connection : G / NPT 1 1/2″, G / NPT 2″
Blocking distance : 1 1/2″: 0.25 m (0.8 ft), 2″:0.35 m (1.15 ft)
Max. measurement distance : Sensor 1-1/5″: 5 m (16 ft), Sensor 2″: 8 m (26 ft)
Communication : 4…20 mA
Certificates / Approvals : ATEX, CSA C/US, IEC Ex, NEPSI
Options : Accessory Enclosed: UNI flange 2″ … 4″
Application limits : For higher resistance: FMU41/42/FDU9x, Foam / high turbulence possible: FMU42/FDU91, Fast filling and discharging rate: FMU90 + FDU9x, Level limit detection: FMU90 + FDU9x